Strain-Specific Isolation of Terpenes Utilizing Microwave-Assisted Extraction

August 23, 2019
Volume: 
2
Issue: 
4
Figure 1
Figure 1 (click to enlarge): An Ethos X microwave system with a 5 L vessel and glass fragrance extraction kit manufactured by Milestone SRL.
Table I: 5 L vessel extraction method
Table I (click to enlarge): 5 L vessel extraction method
Table II: Potency and terpene profile of fresh frozen OGKB 2.0 pre-extraction
Table II (click to enlarge): Potency and terpene profile of fresh frozen OGKB 2.0 pre-extraction
Abstract / Synopsis: 

As the cannabis industry matures, terpene isolation from cannabis plant material has become a primary issue. So far, there have only been two practical applications: steam distillation, which is time consuming and smaller in scale, or CO2 extraction, which requires expensive equipment and an experienced operator. Solvent-free microwave-assisted extraction solves these problems with a cost-effective, efficient solution. The process requires nothing other than water, takes roughly 1 h per run, and yields tetrahydrocannabinol (THC) free, strain-specific terpenes from a variety of starting materials. Throughout this article, I discuss the capabilities of microwave-assisted extraction and how the cannabis industry can utilize it.

Percy Spencer invented the microwave in 1945 (1) and since that time it has revolutionized the way food has been cooked and prepared. However, microwaves have numerous uses outside of the kitchen. By the mid-1970s, chemists began using them for a wide variety of applications in inorganic and organic sample preparation (2) with materials ranging from soils and food to electronic boards (3). This instrumentation has been an asset to the scientific community over the last 40 years and will continue to be. In this article, we are going to discuss the capabilities of this technology in the isolation of strain-specific terpenes from the cannabis plant.

Common Terpene Isolation Methodology

Harvesting terpenes from cannabis is generally completed in two ways. One utilizes steam distillation in a Clevenger apparatus or similar set-up to facilitate terpene removal. The other process utilizes CO2 as the extraction solvent, collecting the terpenes as an initial fraction within the closed loop system. While both processes work adequately, they each have drawbacks. Steam distillation requires a significant amount of heat under a long dwell time to achieve a full extraction. The length of time under heat can have an effect on product quality. It is also difficult to scale in comparison to CO2 and microwave-assisted extraction techniques. While subcritical CO2 is an efficient way to remove terpenes from plant material, the technique lacks the ability to efficiently process wet or fresh frozen material. This is because of the interaction between water and carbon dioxide forming carbonic acid (CO2 + H2O⟷H2CO3) (4), which can cause an acidic pH change in the final product affecting the overall flavor. The implementation of a commercial supercritical CO2 extraction system is also a large initial capital investment that requires an experienced operator to achieve optimal results.

Microwave Theory

Microwave-assisted extraction solves these problems with the introduction of an affordable and efficient system that requires minimal experience to operate. Utilizing a set of magnetrons, the system channels microwaves throughout the sample cavity and uses them as a form of energy to excite polar molecules. In the cannabis application, that polar molecule is water. As the microwaves pass through the sample matrix, every change in the electric field of the wavelength causes a dipole rotation of the water molecules. This rotation generates friction, causing a tremendous amount of heat very rapidly (5).

This heat eventually causes the water to change from its liquid phase to steam. The increase in heat and pressure caused from this steam releases the terpenes from the plant material (6). As the steam begins to exit the microwave cavity into the distillation head, it carries these newly released terpenes with it. The microwave process is more efficient than standard steam distillation because instead of using convection heat, the microwaves heat evenly throughout the sample matrix.

Experimental Design

The development work was done using an Ethos X microwave system with a 5 L vessel and glass fragrance extraction kit manufactured by Milestone SRL (Figure 1). (See upper right for Figure 1, click to enlarge.) The only additional materials needed are water and cannabis biomass. The process works on trim or flower, either freshly harvested or fresh frozen or in cured form. The first portion of the work discussed is done using fresh frozen flower material, followed by applying the same process on cured flower material. The strain used in this development work is OGKB 2.0 and the strain choice was because of inventory constraints at the time of development. The intent was to compare the same strain in both fresh frozen form as well as finished shelf-grade material, and OGKB 2.0 was the only strain we had in both forms at the time. Freshly harvested material, without freezing, is not an option because of Nevada state regulations, as it must be frozen within 2 h of harvest and tested by a third party analytical laboratory before being transferred to a production license. The microwave extraction method used was the same for both varieties of material and can be seen in Table I. (See upper right for Table I, click to enlarge.)

Process and Results

Since fresh frozen cannabis material generally has a water content upwards of 70%, no additional water needs to be added in the process. To begin, the frozen cannabis was removed from a -25 °C freezer and allowed to stand at ambient temperature to thaw for 1 h. Once the plant material had warmed, it was dropped evenly into the material vessel. Packing the material with any type of pressure is not recommended because it creates a less efficient distillation. Once the vessel was filled, it was placed into the microwave cavity of the microwave system and the extraction process was started.

Since the plant was tested as frozen material after harvest, there is a reference point for potency and terpene content that can be seen in Table II. (See upper right for Table II, click to enlarge.) This test panel is done on an “as is” basis, so water content has not been factored out. This accounts for the potency and terpene content being at lower-than-average values.

References: 
  1. E. Conover and A.G. Levine, American Physical Society 24(9), 2 (2015).
  2. J.A. Nobrega and C. Pirola, Microwave Assisted Digestion 1st ed., Milestone Srl (2018).
  3. Titan MPS Applications Notebook, “Great Results Begin With Good Preparation,” Perkin Elmer, www.perkinelmer.com/lab-solutions/resources/docs/APP_Titan-MPS-Applications-Notebook_010773B_01.pdf
  4. A. Morias, et. al., Chemical Reviews 115(1), 6 (2015).
  5. D. Spector, www.businessinsider.com/how-do-microwaves-work-2014-6.
  6. www.doterra.com/US/en/brochures-magazines-living-winter-2013-2014-distilling-essential-oils.
  7. www.restek.com/chromatogram/view/GC_GN1200/terpenes.

Stephen Markle is the Vice President of Production for Planet 13 in Las Vegas, Nevada, and is responsible for all concentrate and infused product manufacturing. Markle has over seven years of experience as an analytical chemist in the nutraceutical and cannabis industries. Direct correspondence to: [email protected]

How to Cite This Article

S. Markle, Cannabis Science and Technology 2(4), 50-57, 76 (2019).